Plan2CAD & Security Drawings
QDOS’s specialty is fire safety drawings, but our Plan2CAD service is for those sites where you have no CAD drawings of the building layout.
WHAT IS PLAN2CAD?
If your building pre-dates the computer-aided design revolution, or if you’ve just lost the electronic files, QDOS will re-draw your building on the Plan2CAD service from your scanned images or photos.
UPDATE YOUR BUILDING PLANS
From a simple layout of the walls to a full re-draw including fixtures and fittings, simply contact us with your scanned images or photos for a competitive price today!
SECURITY DRAWINGS
We can complete all system layout drawings for CCTV, Access Control, and Intruder Alarm systems. Our experienced CAD team is always on hand to complete your multi-disciplined project.
Complexity makes security difficult, so we are here to keep things simple. We create clear and easy-to-understand drawings for your security system, clarifying your design for everyone involved.
FAQS
Fire Alarm Zone Plans
Yes.
BS 5839-1:2017 states that zone plans are required on every system of any size in order to be compliant. If your system doesn’t have a zone plan, the competent person or company maintaining the fire alarm system should note this as a major non-compliance.
See BS 5839-1:2017 46.2 (b).
The fire alarm zone plan should be a diagrammatic representation of the building showing at least the building entrances, main circulation areas and division into zones.
As each building is different there is no ‘one size fits all’ plan or time – each is different.
BS 5839-1:2017 states that a zone plan is,
‘a diagrammatic representation of the building showing at least the building entrances, the main circulation areas and the division into zones, should be sited next to each CIE’ A list alone wouldn’t satisfy this.
Even with good descriptions, someone unfamiliar with the building wouldn’t necessarily know where these areas are, or the extent of them.
If you are a trade supplier of fire alarm systems and/or fire alarm system maintenance services, contact us on 03333 441516 or email hello@qdos.biz
If you need a fire alarm zone plan for your premises, please contact your maintenance provider.
Premises Information
Premises Information Plates show the simplified building plan identifying the main entrances, stairs and lifts.
They also show the fire fighting items such as wet and dry risers and indicate the number of hose lengths the fire and rescue service require from the riser outlets to the furthest room on the floor.
Essential information on the firefighting facilities and plans of the building should be made available to the attending fire and rescue service on arrival to an emergency call.
The premises information plate captures all this information and is displayed clearly and conspicuously on the exterior of the building.
These are usually mounted by the main entrance used by the fire and rescue service when attending an emergency call.
The Premises Information Plate is manufactured using vandal and weather resistant anoprinted aluminium as standard.
A di-bond aluminium version is also available which is weatherproof but not vandal resistant.
Whilst the main types of buildings using premises information plates are high rise, other buildings with particular hazards or irregular internal layouts can also display Premises Information Plates to benefit the attending Fire and Rescue Service.
Fire Escape Plans
Escape plans should be located at strategic points around the building, such as main entry/exit points on each level, adjacent lifts and stairs, at points where occupants can learn the evacuation route and procedure (such as staff rooms or training rooms), or in every room (such as hotel rooms).
All escape plans do not need to be photoluminescent. However, if the premises has a phosphorescent way guidance system, the escape plans may use phosphorescent material, which shall be no less than classification C, according to ISO 17398.
Photoluminescent escape plans from QDOS are printed by HILUX which exceed the classification C, according to ISO 17398.
Once you have sent your enquiry regarding a Fire Escape Plan, we will send a checklist for your drawings and give you a free quote for your project.
Fire System Design
Yes, QDOS are accredited to BAFE SP203 for fire alarm system design. The accreditation is maintained by annual independent inspection from the National Security Inspectorate (NSI).
As a minimum, we require scaled plans of the property requiring a fire alarm system design, with the requested category of fire alarm system.
Additionally, full specifications and section drawings of the building are also extremely helpful in reducing assumptions made whilst designing a system from plan.
BS 5839-1:2017 has examples of the category of systems for various types of premises.
This is usually decided by risk assessment, fire strategy report or the building insurance requirement.
Fire Safety Plans
Fire Safety Plans show all items pertaining to the fire safety of a building, such as the fire alarm system devices, emergency lights, fire extinguishers and signage. Also, the fire compartmentation including fire doors is usually shown.
The Fire Safety Plans should be kept in a Premises Information Box, or anywhere they can be kept safely but accessible for review.
Generally, symbols from BS 1635:1990 are used, due to the age of the standard additional symbols are also used to depict new and modern devices and fittings.
As-Fitted Drawings
As-Fitted (or As Installed) drawings usually show the system layouts of a building and should include any changes/modifications which have occurred on-site from the original drawings.
These drawings are usually required at the end of a project to form part of the project’s handover, provided to the premises manager for the installation of a fire alarm system in accordance with BS 5839-1:2017.
As-Fitted drawings should be kept safely in a Premises Information Box or operation and maintenance manual for the fire alarm system.
Should the fire alarm system be modified in any way, these as-fitted drawings should also be reviewed and revised accordingly.
No. There is no requirement to display the as-fitted-drawings, only the Fire Alarm Zone Plan is required to be displayed by each control panel or repeater panel as part of a compliant system.
General
We can work with existing building plans or re-draw the building using:
DWG files – AutoCAD format which are the standard CAD files using the extension .dwg.
PDF files – Some PDF files are able to convert into AutoCAD format, which can be some original PDF files (created within CAD software) but NOT scanned images. To find out if yours converts, please email cad@qdos.biz and we will verify if your file can be converted.
Plan2CAD – We can create AutoCAD plans from your customer’s old paper copies, scanned drawings or site sketches. Send via scans or good quality photos to cad@qdos.biz or post to our office for a competitive quote. We will return any original drawings at your request, free of charge.
We offer 30-day credit accounts (subject to acceptance), or you can pay online via credit or debit card.
Yes. We can draw the building either from paper copies of the plans, or from your own sketch of the premises. Just upload any images and/or drawings you may have via the Priority Portal, and we’ll let you know the best solution for your project.
Framed, acrylic or photoluminescent zone plans, escape plans and all premises information plates are delivered by courier.
All deliveries direct from QDOS can be tracked and amended with FedEx. Some deliveries from our manufacturing partners may not be tracked live.
Yes. All deliveries can be sent plain label on request.
If you refuse delivery we will automatically be notified and a replacement will be sent. If you accept delivery, please contact us on the day of delivery with any concerns regarding damage or missing items.
Contact Us
Fill out our contact form below with your enquiry and one of our team will get back to you ASAP.